Cfp 2 4 8 zone user manual

Lpcb certified to en54 2 4, ctecs cfp 8 zone conventional fire alarm panel offers an array of user and installerfriendly features at a very competitive price. Lpcb certified to en5424, ctecs cfp 8 zone conventional fire alarm panel offers an array of user and installerfriendly features at a very competitive price. Dfu7004010 rev 1 page 5 of 24 cfp 248 zone lpcb approved fire alarm panel 1. We have 1 alarm sense cfp 4 zone manual available for free pdf download. An overview of the panels access levels three access levels are available at the panel access level 1 general user, access level 2 authorised user and access level 3 engineer. Cfp702 4 lpc cfp 2 zone panel,lpcb approved to en54 2 4,does not extend,code entry cfp704 4 lpc cfp 4 zone panel,lpcb approved to en54 2 4,does not extend,code entry cfp708 4 lpc cfp 8 zone panel,lpcb approved to en54 2 4,does not extend,code entry battery packs bc283 2 24v 1. Haes technologies ltd, unit 3, horton industrial park, west drayton, middlesex, ub7 8jd. Dfu7001010rev1page11of20 to avoid confusion, during the selection process any light in the table of options that was showing a.

User manuals, guides and specifications for your alarm sense cfp 8 zone smoke alarm. Nov 29, 20 a short video explaining how an authorised user can silence and reset a fire alarm condition on a ctec cfp conventional fire alarm panel. Dfu700 rev 3 cfp 248 zone fire alarm panel the primary purpose of a fire alarm system is to provide an early warning of a fire so that people and animals can be evacuated and action taken to stop the fire as soon as possible all according to a predetermined plan. Ctec cfp alarmsense 2, 4 or 8 zone panel discount fire. Gent fire alarm installation manual bercclubphuclo.

Cfp 248 zone conventional fire alarm panel cfp stan dard p anel cfp ec onomy pa nel cfp lpcb appr oved p anel n o n l a t c h i n g z o n e s f c i l i t y z o n e d e l a y f a c i. Dfu700 rev 4 cfp 248 zone fire alarm panel the primary purpose of a fire alarm system is to provide an early warning of a fire so that people and animals can be evacuated and action taken to stop the fire as soon as possible all according to a predetermined plan. Ctec economy 2 4 8 zone fire alarm panel custom kit detector. Dfu7002009 rev 2 cfp 248 zone economy fire alarm panel this equipment must only be installed and maintained by a suitably skilled and technically competent person.

Cfp16 manual aus emergency operation doc01022 i emergency operation press silence buzzer to switch off the panel buzzer. Support worldwide technical support and product information. Lpcb certified to en54 2 4, ctecs cfp 8 zone economy fire alarm panel offers an array of user and installerfriendly features at a very competitive price. Complete the following steps to mount the backplane on a din rail. You need one kit to mount the cfpbp4 on a standard 35 mm din rail. Ctec economy cfp 8 zone conventional fire panel cfp708e4. User manuals fire specialised security systems fire zone alarm. Lpcb certified to en5424, ctecs cfp 8 zone economy fire alarm panel offers an array of user and installerfriendly features at a very competitive price. Ctecs awardwinning cfp conventional fire panel is lpcb certified to the latest revisions of en54 parts 2 and 4 and offers an array of user and installerfriendly features at a very competitive price. Using a number 2 phillips screwdriver with a shank of at least 64 mm 2. Lpcb certified to en54 parts 2 and 4 intuitive userfriendly interface with colourcoded buttons and combined keypadkeyswitch entry to access level 2 2, 4 or 8 alarmsense zone circuits dependent on model purchased. Cfp 28 zone conventional panel en54 eurotech fire safety. This equipment is a piece of class 1 equipment and must be earthed items supplied with. May 16, 2015 this video demonstrates the functioning of the cfp702 4 2 zone fire alarm panel.

Cfp 8 zone fire panel, keypadkeyswitch entry lpcb approved. As1006 cfp 2 zone alarmsense fire panel, keypadkeyswitch entry. Press firmly to seat the cfpai110 on the backplane. Ctec economy 2 4 8 zone fire alarm panel custom kit. Lpcb certified to en5424, ctecs cfp 2, 4, 8 zone conventional fire alarm panel offers an array of user and installerfriendly features at a very competitive.

Instructions and manuals are best downloaded from our individual product pages via the menu bar above. Cfp economy 8 zone conventional fire alarm panel by ctec lpcb certified to en54 2 4, ctecs cfp 8 zone economy fire alarm panel offers an array of user and installerfriendly features at a very competitive price. Dfu7001009 rev 1 cfp 248 zone economy fire alarm panel bs58391. Cfp 248 zone conventional fire alarm panelpanel layout accessing the controlsthe fire alarm panel allows both keyswitch and keypad. Fasten the din rail clip to the cfpbp4 using a number 2 phillips. Cfp msa management interface specification june 8, 2015. Supplied in an attractive flush or surface mountable plastic enclosure, 2, 4 and 8 zone versions are available, each featuring four conventional sounder circuits, class change and alert inputs, onboard fire and. The panel will reenter an alarm state if the hazards have not been. Dfu7004000 rev 5 7 cfp 248 zone lpcb approved fire alarm panel fixing the base to the wall using the five mounting holes provided see figure 3 below, fix the base securely ontointo the wall. As1008 cfp 8 zone alarmsense fire panel, keypadkeyswitch entry. Ctec cfp708 4 standard eight zone fire alarm panel. Includes its own mains power supply that requires its own standby battery supply. Alarm sense cfp 8 zone manuals and user guides, smoke. Designed to comply with en5424 two onboard relays fault and fire new intuitive userfriendly interface with colourcoded buttons and combined keypadkeyswitch entry to access level 2 available with 2, 4 or 8 zone alarmsense zone circuits alarmsense detectors, call points, sounders and beacons can be connected to the.

Dfu7002000 rev 4 7 cfp 248 zone fire alarm panel fixing the base to the wall using the five mounting holes provided see figure 3 below, fix the base securely ontointo the wall. All of these functions and more are explained in detail in this user manual. View online or download alarm sense cfp 4 zone user manual. Dfu7002000 rev 4 cfp 248 zone fire alarm panel this equipment must only be installed and maintained by a suitably skilled and technically competent person. Cfp7084 cfp standard 8 zone conventional fire alarm panel. Ctecs awardwinning cfp conventional fire panels are lpcb certified to en5424 and offer an array of user and installerfriendly features. Ctecs awardwinning cfp conventional fire panel offers an array of user and installerfriendly features at a very competitive price. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Cfp 16 zone expansion card installation sheet doc03051 cfp 16 keypad installation sheet doc03054 are interface board installation sheet doc03062 battery connection installation kit doc03046 zone mimic manual doc01028 acm8ra installation sheet doc03052 intrinsically safe manual doc01029. Access level 1 is the normal user level which is accessible to everyone. Dfu7004000 rev 5 cfp 248 zone lpcb approved fire alarm panel this equipment must only be installed and maintained by a suitably skilled and technically competent person. Ctecs awardwinning cfp conventional fire panel is lpcb certified to en54 parts 2 and 4 and offers an array of user and installerfriendly features at a very competitive price. As1007 cfp 4 zone alarmsense fire panel, keypadkeyswitch entry.

This video demonstrates the functioning of the cfp7024 2 zone fire alarm panel. User manual alarm sense cfp 4 zone user manual 20 pages. Ctec cfp 2, 4 or 8 zone conventional fire panel discount. Press scroll to navigate through multiple alarm events. Manuals and user guides for alarm sense cfp 4 zone. Supplied in an attractive flush or surface mountable plastic enclosure, 2, 4 and 8 zone versions are available, each featuring four conventional sounder circuits, class change and alert inputs, onboard. Cfp economy 8 zone conventional fire alarm panel by ctec. Press silenceresound alarm to switch off any active alarm devices. Cfp economy 8 zone conventional fire alarm panel by ctec lpcb certified to en5424, ctecs cfp 8 zone economy fire alarm panel offers an array of user and installerfriendly features at a. The ctec cfp 8 zone fire alarm panel features a number of different user controls to suit the needs of the application. The following fire alarm manuals are available for download. Ctec economy cfp 8 zone conventional fire panel cfp708e 4. Database contains 1 alarm sense cfp 8 zone manuals available for free online viewing or downloading in pdf. The device must prevent the external power supply voltage from exceeding 42 v if there is a transient overvoltage condition.

How to disableenable zones and other functions on a cfp. Take the fire alarm panel out of its box and undo the two lid screws using the torx key provided. Cfp 248 zone conventional fire alarm panel user responsibilities bs58391 is the british standard code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems for buildings. Sound and visual systems ltd fairfield terrace, newton abbot tq12 2lh. Cfp msa management interface specification june 8, 2015 version 2. Supplied in an attractive flush or surface mountable plastic enclosure, 2, 4. Product overview a powerful conventional fire alarm panel offering an array of user and installerfriendly features at a very competitive price, cfp conventional fire panels are lpcb certified to en54 2 4. Can be used to repeat the functions of a master cfp standard or alarmsense 28 zone fire panel at remote parts of site e. Press reset once the hazards have been neutralized. Fire alarm panel custom kit detector call point sounder. A short video explaining how an authorised user can silence and reset a fire alarm condition on a ctec cfp conventional fire alarm panel.

The alignment keys on the cfpai110 prevent backward insertion. The ctech cfp702 4 2 zone conventional fire alarm panel is lpcb certified to the latest revisions of en54 parts 2 and 4, offers an array of user and installerfriendly features at a very competitive price. Cfp7024 2 zone fire alarm panel demonstration youtube. Fpai110 and cfpai110 operating instructions national. The maximum number of devices per zone is 25, and the panel is suitable for installation with the apollo series 65 smoke and heat detectors. Ctecs lpcb certified twowire cfp alarmsense fire panel is designed to work with apollos alarmsense range of detectors, call points, sounders and beacons. Cfp 2 4 8 zone conventional fire alarm panel user responsibilities bs58391 is the british standard code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems for buildings. The ctech cfp7024 2 zone conventional fire alarm panel is lpcb certified to the latest revisions of en54 parts 2 and 4, offers an array of user and installerfriendly features at a very competitive price. Product overview a powerful conventional fire alarm panel offering an array of user and installerfriendly features at a very competitive price, cfp conventional fire panels are lpcb certified to en5424. Supplied in an attractive flush or surface mountable plastic enclosure, it includes eight detector zones, four conventional sounder circuits, class change and alert inputs, onboard. How to plan and install an intruder alarm honeywell. Cfp 248 zone fire alarm control panel menvier mf9300 124 zone fire. However, for your convenience, the main instructions for each of ctecs product ranges typically our control panel manuals can be downloaded. How to silence and reset a cfp fire alarm panel youtube.

980 1564 232 774 1091 1219 895 432 928 128 1302 358 128 977 1373 1234 800 728 130 493 1356 1521 509 431 396 1194 626 939 745 674 474 391 526 1250 923 561 1373 580 122