Hp workstations for linux installing and configuring sas. Hp bios configuration utility hp client management solutions. Option rom configuration for arrays orcaa simple utility used mainly to configure the first logical drive in a new server before the operating system is loaded hp online array configuration utility for netware cpqonlina more fullfeatured. Hp array configuration utility im trying to run hp array configuration utility on a proliant dl 380 server but i wont get it to work, when internet explorer starts it says the page cannot be displayed. I was thinking make it a little easy to make array so i dont need to. Configuring arrays on hp smart array controllers reference guide. In this video i show you how to setup a raid 1, raid 5 with spare and install os.
If required, refer the computer maintenance and service guide to make available enough physical drives to. You can use the array configuration utility for several tasks such as configuring. This product is covered by a global limited warranty and supported by hp services and a worldwide network of hp authorized channel partners. Feb 19, 20 hp array configuration utility for linux 64bit. Hp acucli is available as a part of the hp integrity essentials foundation pack. Hp 166207b21 smart array 530232 raid controller manual online. As others have mentioned, the raid configuration is usually stored on the drives as well as in the controller. The compaq original smart array controller is configured in scu, while all other compaq array controllers are configured by using the acu array configuration utility. Configuring arrays on hp smart array controllers reference. This guide will help you get up and running with hp s command line array configuration utility acu on ubuntu. Some software requires a valid warranty, current hewlett packard enterprise support contract, or a license fee. Supports windows, rhel, sles and xenserver retail warranty. Hpe proliant dl580 gen9 server user guide hewlett packard. Instalasi hp array configuration utility cli hpacucli pada.
Normally a rescan is triggered automatically by hps array configuration utility either the gui or the commandline variety. Lowprofile pci express form factor ships with a full size bracket for deployment in either a lowprofile or full sized slot. Rightclick the hpe restful interface tool prompt, and then click run as administrator. Click hewlett packard enterprise hpe restful interface tool. Array configuration utility acu array diagnostics utility adu hp insight diagnostics operating system. Hp array configuration utility in a redhat linux server jax. Is it possible to run array configuration utility from hyperv server core 2016.
To configure an array on an hp smart array controller, three utilities are available. Hp proliant microserver gen8 user guide abstract this document is for the person who installs, administers, and troubleshoots servers and storage systems. This package provides the hp bios configuration utility bcu for supported notebook, desktop, and workstation models that are running a supported operating system. Setting up compaq proliant servers using the smartstart cd. Hpacucli is used to create, delete and repair the logical and physical drives on the smart array controllers in hp servers. On the server where the array configuration utility xe is located, be sure that the array configuration utility xe is configured to allow remote access. For the web agent to work properly, you must install the required library or package for the linux distribution see table 2. Then browse to the url on your server in this example 10.
This document is for the person who installs, administers, and troubleshoots servers and storage systems. Read available bios settings and their values from a supported desktop, workstation, or notebook computer set or reset setup password on a supported desktop, workstation, or notebook computer. Configuring arrays on hp smart array controllers reference guide abstract this document identifies, and provides instructions for, the array configuration tools available for hp proliant controller and server products. The devices list on the lefthand side of the screen shows all the identifiable controllers that are connected to the system. Find answers to installing and accessing hp array configuration utility on hyperv core server from the expert community at experts exchange. Where can i download the hp raid array configuration utility the latest hp proliant array configuration utility acu can be downloaded from hp s enterprise website the offline utilty can be downloaded here. Solved hp smart array configuration lost proliant gen8.
System insight manager compatible operating systems microsoft windows server 2003, microsoft windows server 2000, microsoft windows storage server 2003, novell netware 6. Hp management software for linux on proliant servers. For more information about these procedures, refer to the hp array configuration utility user guide. Hp array configuration utility command cheat sheet binary. Although acu is still supported, hpe ssa replaces it starting with proliant gen8 servers.
Configuration details to configure hp smart array controllers, use the hp array configuration utility either hpacuxe8 or hpacucli8 or the offline rombased configuration utility orca run from the smart array s option rom at boot time. During this procedure, the logical drives each keep the same faulttolerance method in the enlarged array that they had in the smaller array. Click start, and navigate to programshp system toolshp array configuration utility. To display the detailed status of the controller and the disk status, execute the following command. Hp assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. When controller detection is complete, select a controller from the list on the left side of the screen. Use the following procedure to configure an integrated striped is volume with the biosbased configuration utility. Hp array configuration utility cli for linux 64bit. There is a hp support documentation about debian gnu linux 6. Configuration details to configure hp smart array controllers, use the hp array configuration utility either hpacuxe8 or hpacucli8 or the offline rombased configuration utility orca run from the smart arrays option rom at boot time. Hp array configuration utility user guide ftp directory listing. There are many gui differences between acu and hpe ssa.
Hp smart array controllers, use the hp array configuration utility either hpacuxe8 or hpacucli8 or the offline rombased configuration utility orca run. This obsolete driver was removed from the kernel in version 4. I have very little experience with hp controllers, but this manual for hp smart array configuration may help. The layout of the tool seems to be the same as we found already in the new hp sum 6. Array configuration utility acu, option rom configuration for arrays orca, systems insight manager, array diagnostic utility adu and smartstart. Run array configuration utility from hyperv server core 2016. The acu has been superceeded by the hpe smart storage administrator. On the remote system, connect to the compaq insight manager xe server port.
As the name suggests, this utility is for hp servers. After you exit from the hardware configuration portion of setup, you will be taken to the array configuration utility if. Hewlett packard enterprise assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. Normally a rescan is triggered automatically by hp s array configuration utility either the gui or the commandline variety. Where can i download the hp raid array configuration utility. This is a somewhat better quality video of hp raid array configuration. Has anyone used the hp array configuration utility command line interface hpacucli. Use the following steps as a guide to set up the lsi 3041e or the onboard lsi controllers for sas raid. This option allows the driver to attempt to operate on any hp smart array hardware raid controller, even if it is not explicitly known.
This package provides the hp bios configuration utility bcu for supported notebook. The hp array configuration utility is a webbased application that helps you configure hp proliant smart2 array controllers, hp proliant smart array controllers, hp proliant integrated smart array controllers, and hp proliant storageworks raid array controllers. Ssa smart storage administrator replaces acu array. Click here to download array configuration utility cli for linux. Installing hp array configuration utility hp acu on ubuntu.
Linux untuk mengecek dan memodifikasi konfigurasi sistem hp arrayraid controller. Software consistency among all smart array family products. To use hpacucli, download and install the latest version of hpacucli rpm from the hp website on your linux server. Array configuration utility i would simply get the smartstart firmware maintenance dvd 9. Hpe smart array sr gen10 can be configured by using either hpe ssa or the smart array configuration utility within the uefi system utilities. Im not at the machine right now, but basically i want to find out what the state of each of the physical disks in my server, i. Hp command line array configuration utility hpacucli provides several. This product is covered by a global limited warranty and supported by hp services and a worldwide network. Unzip the selfextracting downloaded file and copy the perccli.
If required, refer the computer maintenance and service guide to make available enough physical drives to create the raid volume. The hp array configuration utility command line interface hp acucli is a commandlinebased disk configuration tool that can be used to configure and manage smart array controllers and raid array controllers in integrity linux environments. Raid driver installation for red hat enterprise linux. Hpe smart array controllers array configuration, diagnostic. The hp xw8000 and xw9000 and 800 workstation series use an onboard lsi 1064, 1068 or 1068e sas controller, which uses the same bios configuration utility as the lsi 3041e plugin card. Hp array configuration utility and vmware solutions experts. Hpacucli stands for hp array configuration utility cli. Use the following procedure to configure an integrated mirroring extended ime volume with the biosbased configuration utility. Watch this video to learn how to enter the raid configuration utility and set a basic single raid 0 array on an hp server.
Hp ssa replaces the existing hp array configuration utility, or acu, with an updated design and will. Fixes an issue where the boot order would be set incorrectly on some systems. Hp proliant dl360 generation 5 server user guide second edition may 2006 part number 406316002. Both hpe ssa and uefi system utilities can be used to configure the smart array sclass, eclass, and pclass.
If you have esx installed, you can install the hp unix command line utilities for the array configuration utility. After having installed and started the installation, it seemed that this ssa is the replacement for the good old acu array configuration utility. This guide will help you get up and running with hps command line array configuration utility acu on ubuntu. This guide may will be especially useful if you have an hp proliant server, or an hp p400 \ p410 raid card or similar. Hpe proliant dl580 gen9 server user guide abstract this document is for the person who installs, administers, and troubleshoots servers and storage systems. Hp array configuration utility command line interface for. I dont want to steal any credit from its original authors. Me too, so i did some googling and found an awesome cheat sheet.
Nov 10, 2011 this is a somewhat better quality video of hp raid array configuration. The procedure assumes that the system has the required disk and disk controllers. Array configuration utility hewlett packard enterprise. The browser opens and launches acu, which then identifies the controllers that are connected to the system. Feb 16, 2017 watch this video to learn how to enter the raid configuration utility and set a basic single raid 0 array on an hp server. Hp z600 workstation configuring raid devices hp customer.
Hp array confi guration utility 46 you can make an isolated change of just one configuration parameter on one device. Previously, other hpe configuration utilities, including array configuration utility and option rom configuration for arrays, were recommended for storage configuration. By downloading, you agree to the terms and conditions of the hewlett packard enterprise software license. Where can i download the hp raid array configuration utility the latest hp proliant array configuration utility acu can be downloaded from hps enterprise website the offline utilty can be downloaded here. Installing hp array configuration utility hp acu on. Hp smart array p410 controller hewlett packard enterprise.
Click start, and navigate to programs hp system tools hp array configuration utility. Hp bios configuration utility bcu is a free utility that enables you to do the following. We have 1 hp configuring arrays manual available for free pdf download. By downloading, you agree to the terms and conditions of the hewlett packard enterprise software license agreement. Using hp array configuration utility from a virtual machine bitsorbytes mar 14, 2008 5. Run the following command as an administrator to start interactive mode. I dont want to steal any credit from its original authors, but i do think it should be reposted for archival.
830 578 761 695 1438 140 1448 1551 515 22 428 1229 1526 1125 1105 353 914 1485 607 1301 236 604 500 1421 218 1185 726 493 952 392 79 532 42 1451 1041 1028 1118